EBook: Monoclonal Antibody Manufacturing Trends, Challenges, and Analytical Solutions to Eliminate Bioprocessing Bottlenecks

Accurate, actionable protein titer in minutes, not days

EBook: Monoclonal Antibody Manufacturing Trends, Challenges, and Analytical Solutions to Eliminate Bioprocessing Bottlenecks

This Cell Culture Dish ebook explores current challenges in monoclonal antibody production and introduces the HaLCon Analyzer for real-time titer measurements, enhancing bioprocessing efficiency. Discover how real-time monitoring streamlines production, allowing for timely adjustments and cost reduction. Industry experts emphasize its transformative impact, while a panel discussion podcast transcript provides additional insights. An accompanying infographic compares the award-winning HaLCon to traditional methods, aiding in maximizing bioprocessing efficiency.

Visit us at Bioprocess International Europe 2024!
EBook: Monoclonal Antibody Manufacturing Trends, Challenges, and Analytical Solutions to Eliminate Bioprocessing Bottlenecks

Please complete the form to download the e-book.

Thank you for submitting the form. A member of our team will reach out shortly.
Oops! Something went wrong while submitting the form.
Redshiftbio

EBook: Monoclonal Antibody Manufacturing Trends, Challenges, and Analytical Solutions to Eliminate Bioprocessing Bottlenecks

Accurate, actionable protein titer in minutes, not days

Accurate, actionable protein titer in minutes, not days

This Cell Culture Dish ebook explores current challenges in monoclonal antibody production and introduces the HaLCon Analyzer for real-time titer measurements, enhancing bioprocessing efficiency. Discover how real-time monitoring streamlines production, allowing for timely adjustments and cost reduction. Industry experts emphasize its transformative impact, while a panel discussion podcast transcript provides additional insights. An accompanying infographic compares the award-winning HaLCon to traditional methods, aiding in maximizing bioprocessing efficiency.

Visit us at Bioprocess International Europe 2024!
EBook: Monoclonal Antibody Manufacturing Trends, Challenges, and Analytical Solutions to Eliminate Bioprocessing Bottlenecks

Request a Demo Today!

Frequently Asked Questions

How must the sample be prepared for HaLCon?

The sample needs to be filtered through a 0.2 µm or 0.45 µm filter to ensure it is free of cells and cell debris. Alternatively, the sample can be spun down and the supernatant sampled with a syringe. Users doing this need to be careful not to stick the syringe too deep in the centrifuge vial. For users familiar with HPLC, the sample can be prepared as if it were being run on HPLC because HaLCon uses a similar column and pre-column filter.

Does HaLCon have a built-in filter or a separator?

HalCOn does not have a built-in filter for removing samples, that must be done before loading the sample.

What is the HaLCon "trap-and-elute technique" and how does it work?

Trap and elute means the analyte (IgG) is fully captured on the column, everything else passes through, then the analyte is released and the detector sees one peak. In terms of flow it differs from traditional liquid chromatography in that there is no gradient, just 100% reagent A to capture or trap IgG, then 100% reagent B to elute.

How does HaLCon react to other Immunoglobulins and other impurities?

The Tridex uses a Protein A media. Anything not bound to the Protein A passes through the column to waste.

How much sample material or sample volume is required to run HaLCon?

We recommend 100 µL per sample. If you have a lower desired sample volume, please contact us and one of our experts can help evaluate the feasibility of the proposed sample volume.

How do you ensure that no cells from the fermenter enter the HaLCon measuring device?

Samples should be spun down, and care should be taken to not disturb any pellets or to remove the entire sample from the centrifuge tube.  Alternatively, the samples can be filtered through a 0.2 µm or 0.45 µm filter.  

What type of pump is used (traditional binary HPLC pump, peristaltic pump) for HaLCon?

HaLCon uses displacement/dispense pumps.  They work like a syringe pump except they are composed of more durable materials for longer, maintenance-free use. Since HaLCon uses low-pressure Liquid Chromatography, the maximum pressure recommended is 200-250 psi.  

Does HaLCon require any connections, e.g. water or gas, in addition to a power connection?

Nothing else but a power connection is needed.

How can the user determine if the sample purification is functioning correctly when using HaLCon?

The best way to validate performance is by running a control sample of known concentration and verifying that the correct concentration value is returned by the software.

What type of maintenance is required for HaLCon? And, will this maintenance be performed during a yearly PM?

No regular maintenance is required beyond changing the reagent pack and analysis module every 3 months or after running 1,000 samples, whichever comes first.  It is recommended to run a flush before running samples if the system has been idle for a few days.  

Can HaLCon also control the process, such as cooling down or emptying the fermenter when a specific threshold is reached? Or is it solely for monitoring purposes?

HaLCon is purpose-built for measuring protein titer, nothing else.  A sample is added either manually or via an autosampler and HaLCon provides a concentration.  HaLCon is compatible with multiple autosamplers, including the Flownamics Director, which may be able to automate the sampling from a bioreactor.